34 Appendix A Replacing and Upgrading FRUs
Figure A-13. Removing a DIMM Module
7. Hold the new DIMM above the DIMM socket, so its polarization notch is located at the right
end of the DIMM socket.
8. Slowly insert the new DIMM by sliding the end with the metal fingers into the DIMM socket
(see Figure A-14). Stop sliding when the DIMMM is securely seated in the socket.
Figure A-14. Inserting a DIMM
9. Snap the latches into place. Do not use excessive force, because the socket might break.
10. Replace the cover (see section A.1).
11. Power on the DSN-1100 storage system. If error messages relating to memory are
displayed, remove the DIMM and reinstall it, making sure to seat the DIMM firmly in its
socket.