D-Link DSA-3200 Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
12
COMMAND LIST MAXn PRESSURES (Model 3207 Only)
COMMAND SYNTAX LIST H
ARGUMENTS None
DESCRIPTION Lists the 16 maximum pressures stored in the MAXn Variable. This is active
only when MODEL is set to 3207.
EXAMPLE To view the maximum pressure settings for the module in the example of
List Ranges type:
LIST H<CR>
The DSA will return the maximum pressure settings. They could appear as
follows.
SET MAX0 6
SET MAX1 6
SET MAX2 6
SET MAX3 6
SET MAX4 18
SET MAX5 18
SET MAX6 18
SET MAX7 18
SET MAX8 18
SET MAX9 18
SET MAX10 60
SET MAX11 60
SET MAX12 60
SET MAX13 60
SET MAX14 60
SET MAX15 60
NOTE Generally, the maximum pressure setting is 20% greater than the full scale
of the sensor to allow a user some over range indication.
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 51 52

Commentaires sur ces manuels

Pas de commentaire