DWS-1008 CLI Reference Guide
D-Link Systems, Inc.
IP Services Commands
set summertime
Offsets the real-time clock of a switch by +1 hour and returns it to standard time for daylight
savings time or a similar summertime period that you set.
Syntax: set summertime summer-name [start week weekday month hour min
end week weekday month hour min]
summer-name Name of up to 32 alphanumeric characters that describes the
summertime offset. You can use a standard name or any name
you like.
start Start of the time change period.
week Week of the month to start or end the time change. Valid values
are first, second, third, fourth, or last.
weekday Day of the week to start or end the time change. Valid values are
sun, mon, tue, wed, thu, fri, and sat.
month Month of the year to start or end the time change. Valid values
are jan, feb, mar, apr, may, jun, jul, aug, sep, oct, nov, and dec.
hour Hour to start or end the time change - a value between 0 and 23
on the 24-hour clock.
min Minute to start or end the time change - a value between 0 and
59.
end End of the time change period.
Defaults: If you do not specify a start and end time, the system implements the time change
starting at 2:00 a.m. on the first Sunday in April and ending at 2:00 a.m. on the last
Sunday in October, according to the North American standard.
Access: Enabled
Usage: You must first set the time zone with the set timezone command for the offset to work
properly without the start and end values. Configure summertime before you set the
time and date. Otherwise, summertime’s adjustment of the time will make the time
incorrect, if the date is within the summertime period.
Examples: To enable summertime and set the summertime time zone to PDT (Pacific Daylight
Time), type the following command:
DWS-1008# set summertime PDT
success: change accepted